Changes for page ANU Seismic Data Loggers

Last modified by robert on 2025/04/24 14:58

From version 42.1
edited by robert
on 2025/03/03 18:21
Change comment: Rollback to version 36.1
To version 43.1
edited by robert
on 2025/03/03 18:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -100,11 +100,9 @@
100 100  
101 101  This menu displays the status of the stations' GPS connection. The screen lists; UTC time, UTC date, latitude, longitude, altitude, number of satellite connections, and SNR.
102 102  
103 -==== Upon setup ====
103 +* Check that the station is connected to satellites
104 104  
105 -- Check that the station is connected to satellites
106 106  
107 -
108 108  == SD Information ==
109 109  
110 110  The menu lists if the SD card has been initialised, as well as the capacity and space free on the memory card. See "Data card formatting" (above) to see how to format and initialise the inserted SD card.
... ... @@ -122,26 +122,19 @@
122 122  
123 123  The seismometer model and serial number (up to 10 characters) can be set. Seismometer model options include:
124 124  
125 -- Trillium Compact
123 +* Trillium Compact (same for 20 and 120)
124 +* CMG - 3ESP
125 +* Guralp 40T
126 +* LE-3D Lite
127 +* Mark L4C
128 +* Mark L4
126 126  
127 -- CMG - 3ESP
128 -
129 -- Guralp 40T
130 -
131 -- LE-3D Lite
132 -
133 -- Mark L4C
134 -
135 -- Mark L4
136 -
137 137  Additionally, the following settings can be used in place of the seismometer model types: +/- 20V, +/- 10V, +/- 5V
138 138  
139 139  The record on restart option ensures that if the logger dies and is powered back up whilst in the field (due to battery charging cycles or other causes) that the recording will resume.
140 140  
141 -==== Upon setup ====
134 +* Set the sampling rate, station identifier, and network code. Set the appropriate seismometer type. Most importantly, ensure the record on restart setting is checked.
142 142  
143 -- Set the sampling rate, station identifier, and network code. Set the appropriate seismometer type. Most importantly, ensure the record on restart setting is checked.
144 -
145 145  (% class="box errormessage" %)
146 146  (((
147 147  NOTE: Ensure the 'RECORD ON RESTART' option is marked with a cross.
... ... @@ -152,14 +152,12 @@
152 152  
153 153  == STA/LTA Configuration ==
154 154  
155 -The Short Term Average and Long Term Average Configuration screen is no longer used.
146 +The Short Term Average and Long Term Average Configuration screen.. this is a relic for when people weren't recording continuously. Not advised!
156 156  
157 -
158 158  = LogFile Conversion Script =
159 159  
160 160  Both the TSAWR and LPR-200 write logging information as a binary "dat" file which includes GPS time syncs, temperatures, battery power, and position. To convert them into ASCII you can read, use [[THIS PYTHON SCRIPT>>http://auspass.edu.au/field/anusr_log.py]].
161 161  
162 -
163 163  = Instrument Response =
164 164  
165 165  Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. Depending on the output sample rate (e.g. 100 Hz, 250 Hz, 500 Hz, 1000 Hz) amplitude response is consistently flat up to ~~100 Hz but phase response can vary above 1 Hz at 100 Hz (or 10 Hz at 250 Hz).
... ... @@ -173,38 +173,21 @@
173 173  
174 174  = ANU TerraSAWR (Gen 3, FW 3.5a, 2017?- current) =
175 175  
176 -Text here
165 +Words to describe the TSAWR would go here, if needed
177 177  
178 -== Sub-paragraph ==
167 + 
179 179  
180 -XXXX
181 181  
182 -== Sub-paragraph ==
183 -
184 -xx
185 -
186 -=== Sub-sub paragraph ===
187 -
188 -x
189 -
190 -
191 191  = ANU LPR-200 (Gen 2, FW 2.6a/2.7a, 2013 - current) =
192 192  
193 -Text here
172 +Ditto the mighty LPR!
194 194  
195 -== Sub-paragraph ==
196 196  
197 -x
198 -
199 -== Sub-paragraph ==
200 -
201 -x
202 -
203 -
204 204  = ANU "ANUSR" (Gen 1, 2003? - 2013?) =
205 205  
206 -x
177 +This logger has been retired for a long time and has a different instrument response.
207 207  
179 +
208 208  = References =
209 209  
210 210  * [[PDF Manual>>http://auspass.edu.au/field/LPR-200_Instruction_Manual.pdf]]